Skip to content
AMADSAS – Home

Automation and monitoring engineering · Riyadh

Automation that keeps your facility running, and proves it with data

AMADSAS is an automation engineering company that designs, builds, installs and supports control, monitoring and power systems for data centres, pharmaceutical sites and industrial plants in Saudi Arabia, with engineering experience since 2009 and more than 1,000 systems installed.

  1. L1FieldSensors, meters, actuators, cabling
  2. L2ControlPLC, DDC and control panels
  3. L3SupervisionSCADA, alarms, historian
  4. L4EnterpriseReports, dashboards, compliance

Figures from delivered projects

years of engineering since 2009
16+
automation and monitoring systems installed
1,000+
engineers and specialists across design, build and service
190+
operational assets connected to our monitoring platforms
2,000+
data points processed every day
2M+
centralised monitoring deployments in live operation
25+

ABB No.1 Channel Partner in India, FY24 and FY25

  • ISO 9001:2015
  • ISO 14001:2015
  • ISO 45001:2018

How we work

We cover the whole automation pyramid, from the sensor to the boardroom

Most failures and gaps sit between layers: a sensor that never reaches the system, or an alarm that never reaches the person who decides. So we engineer all four layers and connect them as one accountable system.

  1. Layer 1

    Field: trustworthy measurement at the source

    We select and install sensors, meters and actuators, then route, terminate and test every cable before commissioning, because every later decision depends on the first reading being right.

    • Temperature, humidity and differential pressure sensors
    • Energy meters and fuel level instruments
    • Cable routing, termination and insulation testing
  2. Layer 2

    Control: panels we build and test ourselves

    We design and manufacture control and power panels in our own facilities, program the PLCs and DDCs, and run factory acceptance tests before shipping, so panels arrive ready to commission.

    • PLC, DDC and VFD panels
    • MCC, PCC, APFC and medium-voltage panels
    • DG synchronising panels
  3. Layer 3

    Supervision: live visibility and alarms that are never lost

    We connect scattered systems to a central SCADA platform on redundant servers that shows values live, archives them, and escalates any deviation by email and SMS.

    • Redundant SCADA and database servers
    • Alarm and event management
    • Historian and long-term trends
  4. Layer 4

    Enterprise: reports that stand up to an audit

    We turn data into reports, dashboards and tamper-evident audit trails with electronic signatures and role-based access, aligned with 21 CFR Part 11.

    • Data, alarm and audit reports in PDF
    • Energy and PUE dashboards
    • Validation documents per GAMP 5

Centralised monitoring platform

Every utility on one screen, every change on record

Our centralised monitoring platform brings environmental, building, utility and production systems into one redundant SCADA system, with an audit trail, electronic signatures and inspection-ready reports.

Redundant by design
Primary and secondary SCADA servers, replicated databases and a redundant industrial Ethernet ring.
Tamper-evident audit trail
Every change is logged with previous and new value, user, comment and timestamp.
Dual electronic signature
Setpoint changes require role-based access and verification by two signatures.
Multi-channel alarms
Instant alerts by email, SMS and messaging apps.
Illustrative screen with sample data
tags in a single pharmaceutical deployment
520,000
servers in that architecture
8
concurrent web clients
50

Communication protocols

  • Modbus TCP
  • OPC UA
  • BACnet IP
  • SNMP
  • MQTT
  • Profinet
  • EtherNet/IP

Data centre references

Systems running in data centres that cannot go down

A selection of delivered data centre projects and the system handed over at each site.

Selected data centre projects
ClientSiteSystem delivered
Amazon Web ServicesLumina data centreHSD automation
NTT Global Data CentersNav 1HSD automation
NTT Global Data CentersDC09HSD automation
NTT Global Data CentersNav 2 DC03Fuel management system
Reliance Jio InfocommVersovaEPMS and HSD automation
Reserve Bank of IndiaGreenfield data centre, BhubaneswarEPMS and HSD automation
InfineonBengaluru data centreChiller plant management

Manufacturing

Our panels are built and tested in our own facilities before they reach your site

We operate three manufacturing units within more than 47,000 sq ft of facilities, covering CNC punching and bending, laser cutting, wiring and assembly, and quality testing.

manufacturing units
3
sq ft of facilities
47,000+
test facility capacity
1 MW
  • CNC punching
  • CNC bending
  • Laser cutting
  • Wiring and assembly
  • Testing and QA
Control panel line-up before dispatch
Control panel line-up before dispatch
Chiller plant panels in assembly
Chiller plant panels in assembly
Load bank for generator testing
Load bank for generator testing
MCC panels with variable-speed drives
MCC panels with variable-speed drives

Design to AMC

One accountable team for the life of the system

We don’t stop at handover. The team that designed the system maintains and extends it.

Service details
  1. 01

    Study and consulting

    Objectives, site assessment and a solution roadmap.

  2. 02

    Design and engineering

    HLD/LLD architecture, electrical, control and network design.

  3. 03

    Supply and factory testing

    Equipment sourcing and factory acceptance testing before shipping.

  4. 04

    Installation and commissioning

    Installation, integration, testing and performance validation.

  5. 05

    Operation and maintenance

    24x7 monitoring and support, preventive and corrective maintenance.

  6. 06

    Annual maintenance contracts

    A dedicated support team and spare-parts management.

  7. 07

    Upgrades and modernisation

    Technology upgrades, legacy migration and capacity expansion.

Clients

Trusted by operators of critical assets

A selection of clients we have delivered automation, monitoring, power and test systems for.

Delivered projects
  • Amazon Web Services
  • NTT Global Data Centers
  • Reliance Jio
  • Reserve Bank of India
  • Infineon
  • Siemens
  • ABB
  • Honeywell
  • Schneider Electric
  • Emerson
  • Cummins
  • Tata Motors
  • Tata Steel
  • Cipla
  • Serum Institute of India
  • L&T
  • thyssenkrupp
  • Saint-Gobain
  • NTPC
  • Indian Oil
  • HAL

Technology partners

  • ABB
  • Kyland
  • KOENIG
  • Helmholz
  • CUBIC
  • Klemsan
  • Inovance

Start with a low-risk step

Readiness assessment: six weeks, read-only, no commitment

We review alarm, environmental and energy data from your existing systems without changing them, then give you a clear picture of gaps and improvement opportunities before any purchasing decision.

  • Data-integrity gap report against ALCOA+
  • Alarm-response analysis by area
  • Energy baseline with a ranked savings shortlist

Frequently asked questions

What engineers ask before they start

What exactly does AMADSAS do?

We design, build, install and support automation, monitoring and power systems: centralised SCADA platforms, building and environmental monitoring, electrical power monitoring, diesel (HSD) automation and generator synchronisation, control panels and test benches. After handover we support the system under annual maintenance contracts.

Do you work with our existing systems or replace them?

We usually start by integrating with what is already installed, over protocols such as Modbus, BACnet, OPC UA and Profinet, adding an independent monitoring layer without taking control. Replacement or upgrade happens only where an assessment justifies it.

Are your systems aligned with 21 CFR Part 11 for pharmaceutical plants?

Yes. The platform provides a tamper-evident audit trail, electronic signatures, role-based access and PDF reports with user and QA review blocks, and we deliver URS, FS, DS, IQ, OQ and PQ validation documents per GAMP 5.

Where are panels built and how are they tested?

Panels are built in our own manufacturing units and tested at the factory under a factory acceptance test before dispatch, then tested again on site with continuity, insulation and loop checks before commissioning.

Which areas of Saudi Arabia do you cover?

We serve the whole Kingdom from our Riyadh headquarters, backed by our own design, manufacturing and commissioning teams.